The U.S. has roughly 3 million miles of natural gas pipe. Most of it is local distribution. The long-haul backbone is roughly 300,000 miles of high-pressure transmission pipelines that move gas from producing basins to cities, power plants, industry and export terminals.
Three kinds of pipelines
| Type | Job | Typical size and pressure |
|---|---|---|
| Gathering | Collect gas from wells and bring it to processing plants | Small diameter, lower pressure |
| Transmission | Move large volumes long distances | Often 20–42 inches across. Usually about 200 to 1,500 psi. |
| Distribution | Deliver gas to homes and businesses through the local utility (LDC) | Small mains and service lines at low pressure |
Interstate and intrastate pipelines
- Interstate pipelines cross state lines. The Federal Energy Regulatory Commission (FERC) regulates their rates and terms of service, and they must publish notices, capacity and other information publicly. Examples include Transco, Tennessee Gas Pipeline, Texas Eastern, ANR and Northern Natural. These are the pipelines tracked on NatGasPipe.
- Intrastate pipelines operate within one state and are regulated by that state. Texas has an especially large intrastate network.
See the live pipeline map to explore interstate routes and their current notices.
How gas moves: pressure and compression
Gas flows from high pressure to low pressure. Friction in the pipe gradually lowers pressure, so compressor stations, usually every 40–100 miles, boost it again. Most compressors run on gas taken from the pipeline, which is one reason pipelines keep a percentage of shippers' gas as fuel.
Each pipe segment has a maximum allowable operating pressure (MAOP) set for safety. When a pipeline lowers pressure for an inspection, repair or safety order, it may cut how much gas the segment can carry. That kind of event often shows up as a capacity reduction in a pipeline notice.
Line pack
Line pack is the gas stored in the pipe itself by running it at higher pressure. Operators "pack" the line during low demand and "draft" it during peaks. It acts as a short-term buffer, but only a limited one. When line pack runs low on a cold day, pipelines often issue critical notices or operational flow orders.
Points, meters and interconnects
- Receipt point: where gas enters a pipeline, for example from a processing plant or another pipeline.
- Delivery point: where gas leaves a pipeline, for example at an LDC city gate, a power plant or another pipeline.
- Interconnect: a meter station where two pipelines connect, letting gas move from one system to another.
- City gate: the delivery point where an interstate pipeline hands gas to a local utility.
- Meter station: measures volume, pressure and gas quality so everyone can be billed and scheduled accurately.
Each point has a location code, often called a DRN or a pipeline-specific code, that shippers use in nominations.
Mainlines, laterals, zones and hubs
- Mainline: the large trunk line of a pipeline system.
- Lateral: a branch that serves a specific customer, plant or area.
- Zones: many pipelines divide their system into rate zones, for example Transco Zones 1–6. Moving gas across more zones usually costs more.
- Segments and constraint points: named locations where capacity is limited. Notices often refer to them by name, such as a compressor station or meter.
- Market hubs: places where several pipelines meet and gas trades actively, such as Henry Hub in Louisiana. See Markets & Pricing.
Capacity: how much a pipeline can move
Capacity is measured in Dth/d or MMcf/d. Every segment, compressor station and meter has a limit. When requests to ship gas through a segment exceed what it can carry, the pipeline cuts scheduled volumes by priority. That is why capacity reductions from maintenance or outages matter so much to shippers.
Some pipelines are bidirectional and can reverse flow. Many older systems were built to carry Gulf Coast gas north and have since been reversed or expanded to carry Appalachian gas south and west.
Keeping pipelines safe
The U.S. Department of Transportation's Pipeline and Hazardous Materials Safety Administration (PHMSA) sets safety rules for gas pipelines. Operators inspect lines with in-line inspection tools (smart "pigs") that travel inside the pipe, run hydrostatic tests and patrol rights-of-way. Much of this work requires taking capacity offline, so it appears as planned service outages in pipeline notices, especially during the spring and fall maintenance seasons.
- Gathering lines collect, transmission lines move gas long distances, and distribution delivers it locally.
- FERC regulates interstate pipelines. States regulate intrastate lines and local utilities.
- Compressor stations keep gas moving, and they burn gas as fuel.
- Capacity limits at segments, compressors and meters decide how much gas can flow, and outages reduce them.
Key terms
- Transmission pipeline
- A large, high-pressure pipeline that moves gas long distances.
- Compressor station
- A facility that raises gas pressure to keep it flowing.
- MAOP
- Maximum allowable operating pressure, the safety limit for a pipe segment.
- Line pack
- Gas held in the pipeline itself by raising pressure.
- Receipt / delivery point
- Where gas enters or leaves a pipeline.
- Interconnect
- A meter where two pipelines connect.
- City gate
- The delivery point from a transmission pipeline to a local utility.
- Lateral
- A branch line off the mainline.
- Pigging
- Running inspection or cleaning tools through a pipeline.
- PHMSA