Elapsed Prorated Scheduled Quantity (EPSQ) Calculator
If you want to reduce a nomination in the Intraday 1 (ID1), Intraday 2 (ID2) or Intraday 3 (ID3) cycle, the reduction is limited by elapsed proration: you can't nominate less than the gas that will already have flowed by the time the new cycle takes effect.
Enter your scheduled quantities for each cycle below (Dth/day). The calculator shows the minimum scheduled quantity you can nominate in each intraday cycle and the maximum cut from what is currently scheduled.
Note: nominations can be cut to zero up to the Evening cycle, because no gas has flowed for that gas day yet when the Timely and Evening deadlines pass. EPSQ applies only to the intraday cycles. Leave a cycle blank if you didn't change your nomination in it; it then carries forward the previous cycle's quantity.
Standard NAESB gas day (Central time)
- Timely / Evening9:00 AM · 0 h elapsed
- ID12:00 PM · 5 h elapsed
- ID26:00 PM · 9 h elapsed
- ID310:00 PM · 13 h elapsed
Each intraday cycle takes effect partway through the gas day. Gas flows evenly across the day, so the hours already gone set the floor for your new nomination.
Compute ID1Effective 2:00 PM · 5 of 24 hours elapsed
Compute ID2Effective 6:00 PM · 9 of 24 hours elapsed
Compute ID3Effective 10:00 PM · 13 of 24 hours elapsed
How it's calculated
Gas is assumed to flow at an even hourly rate (quantity ÷ 24) at whatever was scheduled at the time. The minimum you can nominate is the gas that will have flowed by the time the new cycle takes effect:
- ID1 (2 PM):
Evening × 5/24 - ID2 (6 PM):
Evening × 5/24 + ID1 × 4/24 - ID3 (10 PM):
Evening × 5/24 + ID1 × 4/24 + ID2 × 4/24
Max cut = your latest scheduled quantity − the minimum. A blank cycle carries forward the cycle before it (a blank Evening uses Timely). Results are rounded to whole Dth.
For planning only. Each pipeline applies its own tariff rules, and some use different cycle times or rounding. Always confirm with the pipeline's EBB or scheduling desk before nominating.